Safety of Oxygen Plant
All personnel being employed for work in connection with oxygen/rich air should
be cautioned concerning the hazards involved and precautions to be observed.
WARNING ABOUT OXYGEN GAS PLANTS:
Oil grease or similar substances must not be allowed to come into contact
with compressed oxygen or liquid oxygen. Contact of this substance with oxygen
may result in an explosion. Personnel working in an area of possible oxygen
concentration, such as near an oxygen vent or a liquid oxygen spillage, or
in a trench where oxygen seepage and concentration might occur, must ensure
that their clothing is free from contaminations of oxygen before lighting
a cigarette or approaching a naked flames. It is essential that the clothes
be dries for at least 15 minutes before approaching a flame after any such
contamination.
The following precautions must be strictly observed Oxygen Gas Plant, Nitrogen
Gas Plant, Acetylene Gas Plant at all times:
1: Thoroughly wash all oxygen fittings, valves and parts with clean Tricolor
Ethylene / carbon tetra chloride (CTC) before installation. Never use petrol,
kerosene or otherhydrocarbon solvents for this purpose. All tubing, lines valves
etc. to be used in oxygen service, must be of an approved type and must be thoroughly
degreased and blown out with clean oil-free compressed air or Nitrogen before
being placed in service.
2: Do not permit the release of Acetylene or other flammable gases in the
vicinity of the plant air intake. A concentration of Acetylene exceeding 5
parts per million in liquid oxygen may explode with extreme violence. Strict
supervision is essential to minimize the possibility of contamination.
3: The plant and the plant vicinity must be kept clean and free from abstractions
at all times. Any oil leak within the plant surrounding must be rectified
without delay. Oil spillage must be cleaned up immediately using rag and carbon
Tetra Chloride.
4: Do not lubricate oxygen valves, regulators, gauges or fitting with oil
or any other substance.
5: Ensure that insulation removed from the Air Separator jacket is not contaminated
with oil or other inflammable materials. Personnel carrying out maintenance
on the Air Separation Plant equipment must wear clean overalls and their hands
and tools must be free of oil. This ensures that the insulation and equipment
within the jacket is not contaminated with oil. Should contamination take
place the affected materials must be discarded and replaced by clean new material?
6: Do not fasten electric conduits to the plant or its pipelines.
7: Do not use oxygen as a substitute for compressed air, spark present in
an atmosphere of oxygen will immediately burst into flame.
Contact Us
Mr.Bharat (CEO)
Export Manager
Better Deal Machinery (P) Ltd.
Address :UV-67, Phase - IV, Udyog Vihar, Gurgaon, Haryana -122 001
(10 kms. from New Delhi International Airport)
Phone: +91-124-5519870; +(91)-(124)-4386230
Mobile: +91-9871056668;
Fax: +(91)-(124)-4386231
Email: sales@bdmexport.com
| Oxygen Plant | Salient
Features | Process Description
| Technical Specifications
|
| BDM Technical | Safety
of Oxygen Plant |
Home | About Us | Contact
Us | Query |
Email