S.No.ModelUB-25UB-30UB-40UB-50
1Capacity Oxygen Nitrogen25CuM/Hr.
80 CuM/Hr.
30 CuM/Hr.
100 CuM/Hr.
40 Cum/Hr.
150 Cum/Hr.
50 Cum/Hr.
200 Cum/Hr.
2Purity
(Optional upto 99.999%)

99.6%
96%-96.6%

99.6%
96%-96.6%

99.6%
96%-96.6%

99.6%
96%-96.6%
3Power Connected55 KW70 KW80 KW95 KW
4Power Consumed (abt.)40 KW45 KW60 KW70 KW
5Power Supply415 Volts415 Volts415 Volts415 Volts
6Air Capacity150 Cum/Hr200 Cum/Hr.250 Cum/Hr.300 Cum/Hr.
7Starting Pressure60 Kg/sq.cm.55 Kg/sq.cm.55 Kg/sq.cm.55 Kg/sq.cm.
8Working Pressure (abt)50 Kg/sq.cm.40Kg/sq.cm40Kg/sq.cm40Kg/sq.cm
9Starting Time (After Defrost)8 Hours8 Hours7 Hours7 Hours
10Starting Time (After Tripping)40 Mts.40 Mts.40 Mts.40 Mts.
11Areas Required6M x 8 M6 M x 10 M8 M x 10M8 M x 12 M
12Assembly Height7 M7 M7.5 M7.5 M
13Weight (About)14 Tons16 Tons18 Tons19 Tons
14Air Separation ColumnType-BoschiType-BoschiType-BoschiType-Boschi


1. Data for 500m3/hr oxygen/nitrogen plant available separately.
2. Skid Mounted Version available.
3. All capacities are at design suction conditions of 15 ° c & 50 % RH and 0.03% co2 and specified tolerance.
4. For filling high-pressure nitrogen upto 99.999% simultaneously with oxygen production cylinders we can provide an additional nitrogen pump and nitrogen exchanger.
5. For compressed nitrogen gas at 0.1 Kg /cm2 to 1.1 upto 155 bar or higher a separate nitrogen compressor can be installed with a nitrogen cylinder filling manifold.
6.
About 3% of nitrogen gas is used for the regeneration of the molecular sieve battery and nitrogen cascade cooler.

MEDIUM CAPACITY
S.No.ModelUB-60UB-80UB-100UB-150
1Capacity Oxygen Nitrogen60 CuM/Hr.
200 CuM/Hr.
80 CuM/Hr.
250 CuM/Hr.
100 Cum/Hr.
300 Cum/Hr.
150 Cum/Hr.
500 Cum/Hr.
2Purity
Oxygen
Nitrogen
(Optional)

99.6%
96%-99.99%

99.6%
96%-99.99%

99.6%
96%-99.99%

99.6%
96%-99.99%
3Power Connected110 KW130 KW150 KW250 KW
4Power Consumed (abt.)88 KW95 KW105 KW165 KW
5Power Supply415 Volts415 Volts415 Volts415 Volts
6Air Capacity400 Cum/Hr400 Cum/Hr.600 Cum/Hr.900 Cum/Hr.
7Starting Pressure45 Kg/sq.cm.45 Kg/sq.cm.45 Kg/sq.cm.45 Kg/sq.cm.
8Working Pressure (abt)40 Kg/sq.cm.38 Kg/sq.cm36 Kg/sq.cm36 Kg/sq.cm
9Starting Time (After Defrost)8 Hours7Hours6 Hours6 Hours
10Starting Time (After Tripping)40 Mts.30 Mts.20 Mts.20 Mts.
11Areas Required12M x 15 M12 M x 15 M14 M x 15M14M x 15 M
12Assembly Height8.0 M9.0 M9.5 M9.5 M
13Weight (About)20 Tons25 Tons30 Tons40Tons
14Air Separation ColumnType-BoschiType-BoschiType-BoschiType-Boschi

HIGH CAPACITY
S.No.Model#FBB730UB-200UB-300UB-400UB-500
1Capacity Oxygen Nitrogen200 CuM/Hr. 800
CuM/Hr.
300 CuM/Hr.
1200 CuM/Hr.
400 Cum/Hr.
1400 Cum/Hr.
500 Cum/Hr.
2000 Cum/Hr.
2Purity Oxygen Nitrogen(Optional)99.6% 96%-99.99%99.6% 96%-99.99%99.6% 96%-99.99%99.6% 96%-99.99%
3Power Connected300 KW400 KW600 KW750 KW
4Power Consumed (abt.)220 KW330KW400 KW500KW
5Power Supply415 Volts415 Volts415 Volts415 Volts
6Air Capacity1200 Cum/Hr1800 Cum/Hr.2400 Cum/Hr.3000 Cum/Hr.
7Starting Pressure45 Kg/sq.cm.45 Kg/sq.cm.45 Kg/sq.cm.45 Kg/sq.cm.
8Working Pressure (abt)36Kg/sq.cm.36Kg/sq.cm30Kg/sq.cm30Kg/sq.cm
9Starting Time (After Defrost)6Hours5Hours5Hours5 Hours
10Starting Time (After Tripping)20 Mts.20 Mts.20 Mts.20 Mts.
11Areas Required14M x 15 M15M x 16 M15M x 18M18M x 20M
12Assembly Height9.5 M9.5 M10 M10 M
13Weight (About)50 Tons60 Tons70 Tons80Tons
14Air Separation ColumnType-BoschiType-BoschiType-BoschiType-Boschi

Higher Capacity

7.
All capacities are at design suction conditions of 15 ° c & 50 % RH and 0.03% co2 and specified tolerance.
8. For filling high-pressure nitrogen upto 99.999% simultaneously with oxygen production cylinders we can provide an additional nitrogen pump and nitrogen exchanger.
9. For compressed nitrogen gas at 0.1 Kg /cm2 to 1.1 upto 155 bar or higher a separate nitrogen compressor can be installed with a nitrogen cylinder filling manifold.
10. About 3% of nitrogen gas is used for the regeneration of the molecular sieve battery and nitrogen cascade cooler.

Technical Specifications Query Form

(* represents compulsory fields)
*Your Name :  
*Organization :  
*Your Country :  
*Tel No. : (Include Country/Area Code)  
*Your E-Mail Address :  
Address :  


Contact Us
ING. L&A. Boschi (India)
R-19, Hauz Khas Enclave
New Delhi - 110016, India
Phone: +(91)-(124)-4386250 ; (International calls only)
Mobile: +(00)-(91)-9810626301 (+(00)-(91)-9871872626 International marketing calls only)
Fax: +(00)-(91)-9810626301 (+(00)-(91)-9871872626 International marketing calls only)
Email: info@universalo2.com, info@universalboschi.com

Postal Address
A104/2, Okhla Industrial Area Phase - II,
New Delhi - 110020. India.




| Oxygen Plant | Salient Features | Process Description | Technical Specifications |
| Universal Boschi | Safety of Oxygen Plant |


Home | About Us | Contact Us | Query | Email
High Point Designs